Agenda item

Planning Application DC/18/2243/HH & DC/18/2244/LB - Manor House, Church Road, Great Barton, Bury St Edmunds (Report No: DEV/SE/19/010)

Report No: DEV/SE/19/010

 

Householder Planning Application - single storey rear extension with associated alterations

Minutes:

Householder Planning Application - single storey rear extension with associated alterations

 

This application had been referred to the Development Control Committee as a St Edmundsbury Borough Councillor Sarah Broughton was the applicant.

 

Great Barton Parish Council were in support of the application.  Officers were recommending that both planning permission and the associated Listed Building Consent be approved, subject to conditions, as set out in Paragraphs 11 and 12 of Report No DEV/SE/19/010.

 

A motion for approval, as per the Officer recommendation, was moved and seconded.

 

Upon being put to the vote and with the vote being unanimous, it was resolved that

 

Decision

 

(A)     Planning permission be GRANTED subject to the following conditions:

 

1.   The development hereby permitted shall be begun not later than 3 years from the date of this permission.

2.   The development hereby permitted shall not be carried out except in complete accordance with the details shown on the approved plans and documents.

 

(B)     Listed building consent be GRANTED subject to the following conditions:

 

1.   Time limit: The development hereby permitted shall be begun not later than 3 years from the date of this permission.

2.   Compliance with plans: The development hereby permitted shall not be carried out except in complete accordance with the details shown on the approved plans and documents.

3.   Window details 09OO: No works involving new/replacement windows shall take place until elevation(s) to a scale of not less than 1:10 and horizontal and vertical cross-section drawings to a scale of 1:2 fully detailing the new/ replacement windows to be used (including details of glazing bars, sills, heads and methods of opening and glazing) have been submitted to and approved in writing by the Local Planning Authority. Unless otherwise approved in writing by the Local Planning Authority all glazing shall be face puttied. The works shall be carried out in complete accordance with the approved details.

4.   Door details 09PP:

No works involving new/replacement doors shall take place until elevation(s) to a scale of not less than 1:10 and horizontal and vertical cross-section drawings to a scale of 1:2 fully detailing the new/ replacement internal/external doors and surrounds to be used (including details of panels and glazing where relevant) have been submitted to and approved in writing by the Local Planning Authority. Unless otherwise approved in writing by the Local Planning Authority all glazing shall be face puttied. The works shall be carried out in complete accordance with the approved details.

5.   Sample of external materials 09D ii:

No development above ground level shall take place until details in respect of the following have been submitted to and approved in writing by the Local Planning Authority.

a.    Samples of external materials and surface finishes

6.   Sample panel of flintwork 09CC :

No development above ground level shall take place until details of the following have been submitted to and approved in writing by the Local Planning Authority: 

(i)Sample panel(s) of all new facing brickwork/ flintwork shall be constructed on site showing the proposed brick types, colours, textures, finishes/dressings of the flint; face bond; and pointing mortar mix and finish profile and shall be made available for inspection by the Local Planning Authority;

i)   The materials and methods demonstrated in the sample panel(s) shall be approved in writing by the Local Planning Authority.

 The approved sample panel(s) shall be retained on site until the work is completed and all brickwork shall be constructed in all respects in accordance with the approved details.

7.      Foundation design - A detailed design scheme of the proposed foundations to the relevant location shall be submitted to and approved in writing by the LPA to demonstrate the existing underground structure will not be affected by the proposal.